24980 Allergen, Banana, IgE (BANA)

Allergen, Banana, IgE (BANA)
Test Code: ALBANSO
Synonyms/Keywords
​​Musa spp, Plantain
Useful For

Establishing a diagnosis of an allergy to bananas

Defining the allergen responsible for eliciting signs and symptoms

Identifying allergens:

-Responsible for allergic disease and/or anaphylactic episode

-To confirm sensitization prior to beginning immunotherapy

-To investigate the specificity of allergic reactions to insect venom allergens, drugs, or chemical allergens

Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
Serum​ Serum Separator Tube (SST) ​Red Top Tube (RTT) ​0.5 mL for every 5 allergens requested
For 1 allergen: 0.3 mL/For more than 1 allergen: (0.05 mL x number of allergens) + 0.25 mL dead space
Specimen Stability Information
Specimen Type Temperature Time
Serum​ ​ Refrigerated (preferred)​ 14 days​
​Frozen ​90 days
Interference

Testing for IgE antibodies is not useful in patients previously treated with immunotherapy to determine if residual clinical sensitivity exists, or in patients in whom the medical management does not depend upon identification of allergen specificity.

Some individuals with clinically insignificant sensitivity to allergens may have measurable levels of IgE antibodies in serum, and results must be interpreted in the clinical context.

False-positive results for IgE antibodies may occur in patients with markedly elevated serum IgE (>2,500 kU/L) due to nonspecific binding to allergen solid phases.

Performing Laboratory Information
Performing Location Day(s) Test Performed Report Available Methodology/Instrumentation
Mayo Clinic Laboratories​ Monday through Friday
1 to 3 days
Fluorescence Enzyme Immunoassay (FEIA)
Reference Lab
Reference Range Information
Performing Location Reference Range
Mayo Clinic Laboratories​
ClassIgE kU/LInterpretation
0<0.35Negative
​0/1
0.10-0.34
Borderline/equivocal
1

0.35-0.69Equivocal
20.70-3.49Positive
33.50-17.4Positive​
417.5-49.9Strongly positive
550.0-99.9Strongly positive
6> or =100Strongly positive

Reference values apply to all ages.

Interpretation

Detection of IgE antibodies in serum (Class 1 or greater) indicates an increased likelihood of allergic disease as opposed to other etiologies and defines the allergens that may be responsible for eliciting signs and symptoms.

The level of IgE antibodies in serum varies directly with the concentration of IgE antibodies expressed as a class score or kU/L.

Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
86003​
Synonyms/Keywords
​​Musa spp, Plantain
Ordering Applications
Ordering Application Description
​Cerner ​Allergen, Banana IgE (BANA)
​COM ​Allergen, Banana, IgE (BANA)
If the ordering application you are looking for is not listed, contact your local laboratory for assistance.
Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
Serum​ Serum Separator Tube (SST) ​Red Top Tube (RTT) ​0.5 mL for every 5 allergens requested
For 1 allergen: 0.3 mL/For more than 1 allergen: (0.05 mL x number of allergens) + 0.25 mL dead space
Specimen Stability Information
Specimen Type Temperature Time
Serum​ ​ Refrigerated (preferred)​ 14 days​
​Frozen ​90 days
Interference

Testing for IgE antibodies is not useful in patients previously treated with immunotherapy to determine if residual clinical sensitivity exists, or in patients in whom the medical management does not depend upon identification of allergen specificity.

Some individuals with clinically insignificant sensitivity to allergens may have measurable levels of IgE antibodies in serum, and results must be interpreted in the clinical context.

False-positive results for IgE antibodies may occur in patients with markedly elevated serum IgE (>2,500 kU/L) due to nonspecific binding to allergen solid phases.

Useful For

Establishing a diagnosis of an allergy to bananas

Defining the allergen responsible for eliciting signs and symptoms

Identifying allergens:

-Responsible for allergic disease and/or anaphylactic episode

-To confirm sensitization prior to beginning immunotherapy

-To investigate the specificity of allergic reactions to insect venom allergens, drugs, or chemical allergens

Reference Range Information
Performing Location Reference Range
Mayo Clinic Laboratories​
ClassIgE kU/LInterpretation
0<0.35Negative
​0/1
0.10-0.34
Borderline/equivocal
1

0.35-0.69Equivocal
20.70-3.49Positive
33.50-17.4Positive​
417.5-49.9Strongly positive
550.0-99.9Strongly positive
6> or =100Strongly positive

Reference values apply to all ages.

Interpretation

Detection of IgE antibodies in serum (Class 1 or greater) indicates an increased likelihood of allergic disease as opposed to other etiologies and defines the allergens that may be responsible for eliciting signs and symptoms.

The level of IgE antibodies in serum varies directly with the concentration of IgE antibodies expressed as a class score or kU/L.

For more information visit:
Performing Laboratory Information
Performing Location Day(s) Test Performed Report Available Methodology/Instrumentation
Mayo Clinic Laboratories​ Monday through Friday
1 to 3 days
Fluorescence Enzyme Immunoassay (FEIA)
Reference Lab
For billing questions, see Contacts
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
86003​