Skip Ribbon Commands
Skip to main content
Sign In

22524 Hemoglobin

Hemoglobin
Test Code: HGB
Useful For
Used to detect, confirm, monitor, or rule out a wide range of hematologic disorders, or to evaluate and manage the hematologic effects of treatments (radiation, chemotherapy, medications) or other conditions (illnesses and injuries).
Specimen Requirements
 
 
Fasting Required Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
No​ Whole Blood​EDTA Lavender Top Tube (LTT)​EDTA Pink Top Tube (PTT)​

2 mL​ One lavender top micro collection tube or 1.0 mL in    3 mL lavender​ One lavender top micro collection tube with  0.5 mL​
Royal Blue Top Tube (BD trace element, K2 EDTA)​
Collection Processing Instructions
Invert specimen at least 5-6 times in order to facilitate mixing and prevent coagulation.
Specimen Stability Information
Specimen Type Temperature Time
Whole blood​ Ambient​ <24 hours​
Refrigerated​ <48 hours​
Refrigerated​ >48 hours may be reported with additional comments​
Rejection Criteria
Clotted
Grossly Hemolyzed​
Diluted with IV or tissue fluid​
Frozen​
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
​Beaver Dam
​Monday through Sunday
​Less than 2 hours
​Laser Flow Cytometry/Sysmex XN-2000 ​
Bloomer​
​Monday through Friday ​Less than 2 hours​ ​Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Cadott ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Chetek ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Chippewa Falls ​​Monday through Friday ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Colby/Abbotsford ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Cornell ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Cumberland ​​Monday, Tuesday, Thursday Friday
​Less than 2 hours​ Hemocue 201
​Weston
​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Eagl​e River ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Eau Claire ​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Park Falls​
​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Hayward ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Ladysmith Medical Center ​​Monday through Sunday ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Lake Hallie ​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Lakeview Medical Center ​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Marshfield ​Monday through Sunday​ ​Less than 2 hours​ Unicel Beckman Coulter DxH800​
​Menomonie ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Mercer ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Merrill ​Monday through Saturday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Minocqua ​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Mosinee ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
Neillsville​​Monday through Sunday​​Less than 2 hours​Electrical Impediance/Beckman Coulter DXH600
​Oakwood ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Phillips ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
Rhinelander​ ​Monday through Friday ​Less than 2 hours Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Stettin ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Stevens Point ​​Monday through Friday ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Wausau ​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Wisconsin Rapids ​​Monday through Friday ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
Wittenberg​ ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
Test Information
​This test is included in CBC without differential  (HGMP), CBC with Automated Differential (HGMPA) or CBC with  Manual Differential (HGMPM).
Reference Range Information
Performing Location Reference Range
Marshfield​                    Newborn: 15.0 - 24.0 g/dL 
            1 - 23 months: 10.5 - 14.0 g/dL 
                 2 - 9 years: 11.5 - 14.5 g/dL
Male:     10 - 17 years: 12.5 - 16.1 g/dL
Male:          18+ years: 12.9 - 17.3 g/dL
Female: 10 - 17 years: 12.0 - 15.0 g/dL
Female:      18+ years: 11.7 - 15.5 g/dL ​
See Critical Value List for list of current critical values.​
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
85018​
Ordering Applications

Ordering Application Description
​Cerner ​Hemoglobin Level
If the ordering application you are looking for is not listed, contact your local laboratory for assistance.
Specimen Requirements
 
 
Fasting Required Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
No​ Whole Blood​EDTA Lavender Top Tube (LTT)​EDTA Pink Top Tube (PTT)​

2 mL​ One lavender top micro collection tube or 1.0 mL in    3 mL lavender​ One lavender top micro collection tube with  0.5 mL​
Royal Blue Top Tube (BD trace element, K2 EDTA)​
Collection Processing
Invert specimen at least 5-6 times in order to facilitate mixing and prevent coagulation.
Specimen Stability Information
Specimen Type Temperature Time
Whole blood​ Ambient​ <24 hours​
Refrigerated​ <48 hours​
Refrigerated​ >48 hours may be reported with additional comments​
Rejection Criteria
Clotted
Grossly Hemolyzed​
Diluted with IV or tissue fluid​
Frozen​
Useful For
Used to detect, confirm, monitor, or rule out a wide range of hematologic disorders, or to evaluate and manage the hematologic effects of treatments (radiation, chemotherapy, medications) or other conditions (illnesses and injuries).
Reference Range Information
Performing Location Reference Range
Marshfield​                    Newborn: 15.0 - 24.0 g/dL 
            1 - 23 months: 10.5 - 14.0 g/dL 
                 2 - 9 years: 11.5 - 14.5 g/dL
Male:     10 - 17 years: 12.5 - 16.1 g/dL
Male:          18+ years: 12.9 - 17.3 g/dL
Female: 10 - 17 years: 12.0 - 15.0 g/dL
Female:      18+ years: 11.7 - 15.5 g/dL ​
See Critical Value List for list of current critical values.​
For more information visit:
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
​Beaver Dam
​Monday through Sunday
​Less than 2 hours
​Laser Flow Cytometry/Sysmex XN-2000 ​
Bloomer​
​Monday through Friday ​Less than 2 hours​ ​Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Cadott ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Chetek ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Chippewa Falls ​​Monday through Friday ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Colby/Abbotsford ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Cornell ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Cumberland ​​Monday, Tuesday, Thursday Friday
​Less than 2 hours​ Hemocue 201
​Weston
​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Eagl​e River ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Eau Claire ​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Park Falls​
​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Hayward ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Ladysmith Medical Center ​​Monday through Sunday ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Lake Hallie ​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Lakeview Medical Center ​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Marshfield ​Monday through Sunday​ ​Less than 2 hours​ Unicel Beckman Coulter DxH800​
​Menomonie ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Mercer ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Merrill ​Monday through Saturday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Minocqua ​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Mosinee ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
Neillsville​​Monday through Sunday​​Less than 2 hours​Electrical Impediance/Beckman Coulter DXH600
​Oakwood ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Phillips ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
Rhinelander​ ​Monday through Friday ​Less than 2 hours Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Stettin ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
​Stevens Point ​​Monday through Friday ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Wausau ​Monday through Sunday​ ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
​Wisconsin Rapids ​​Monday through Friday ​Less than 2 hours​ Electrical Impediance/Beckman Coulter DXH600
Wittenberg​ ​​Monday through Friday ​Less than 2 hours​ Spectrophotmetric/Beckman Coulter ACT5 DIFF-CP
For billing questions, see Contacts
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments