25234 HLA-ABC Low Resolution (Class 1)

HLA-ABC Low Resolution (Class 1)
Test Code: MISC
Synonyms/Keywords
Lab Ref Code:  2302, histocompatibility, transplant testing, work-up on recipient or donor
Useful For
​Histocompatibility, transplant testing, work-up on recipient or donor.
Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
Whole blood or cord blood​ ​EDTA Lavender Top Tube ​14 mL ​5 mL
Buccal swabs​ ​4 swabs ​3 swabs
Collection Processing Instructions

​Indicate on specimen tube and requisition if sample is whole blood or cord blood. Contact Versiti lab if sending cord blood or DNA.

See Blood Center # 2553 HLA DRB1 and DQB1/DQA1 Low Resolution (DQ2 may be requested)Typing (Class II) for complete transplant testing panel.

Specimen Stability Information
Specimen Type Temperature Time
​Whole blood or cord blood ​Ambient ​7 days
​Buccal swabs ​Ambient ​7 days
Rejection Criteria
Specimens received frozen.
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
Versiti Monday through Friday​ ​5-7 days ​PCR-rSSO, -SSP (melt curve analysis), and/or Direct DNA Sequencing
Reference Range Information
Performing Location Reference Range
Versiti Interpretive report​
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​81372
Synonyms/Keywords
Lab Ref Code:  2302, histocompatibility, transplant testing, work-up on recipient or donor
Ordering Applications
Ordering Application Description
If the ordering application you are looking for is not listed, contact your local laboratory for assistance.
Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
Whole blood or cord blood​ ​EDTA Lavender Top Tube ​14 mL ​5 mL
Buccal swabs​ ​4 swabs ​3 swabs
Collection Processing

​Indicate on specimen tube and requisition if sample is whole blood or cord blood. Contact Versiti lab if sending cord blood or DNA.

See Blood Center # 2553 HLA DRB1 and DQB1/DQA1 Low Resolution (DQ2 may be requested)Typing (Class II) for complete transplant testing panel.

Specimen Stability Information
Specimen Type Temperature Time
​Whole blood or cord blood ​Ambient ​7 days
​Buccal swabs ​Ambient ​7 days
Rejection Criteria
Specimens received frozen.
Useful For
​Histocompatibility, transplant testing, work-up on recipient or donor.
Reference Range Information
Performing Location Reference Range
Versiti Interpretive report​
For more information visit:
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
Versiti Monday through Friday​ ​5-7 days ​PCR-rSSO, -SSP (melt curve analysis), and/or Direct DNA Sequencing
For billing questions, see Contacts
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​81372