Skip Ribbon Commands
Skip to main content
Sign In

26074 Allergen IgE, Green String Bean (GSTB)

Allergen IgE, Green String Bean (GSTB)
Test Code: ALGSTSO
Synonyms/Keywords
Bean
Common Bean
French Bean
Green Bean
Haricot Bean
Phaseolus vulgaris
Snap Bean
Wax Bean
Useful For

Establishing the diagnosis of an allergy to green string bean

Defining the allergen responsible for eliciting signs and symptoms 

Identifying allergens:

- Responsible for allergic disease and/or anaphylactic episode

- To confirm sensitization prior to beginning immunotherapy

- To investigate the specificity of allergic reactions to insect venom allergens, drugs, or chemical allergens

Testing for IgE antibodies is not useful in patients previously treated with immunotherapy to determine if residual clinical sensitivity exists, or in patients in whom the medical management does not depend upon identification of allergen specificity.

Specimen Requirements
Fasting Required Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
​No ​Serum Serum Separator Tube (SST) ​Red Top Tube (RTT)
​0.3 mL
Collection Processing Instructions

​For 1 allergen: 0.3 mL
For more than 1 allergen: (0.05 mL x number of allergens) + 0.25 mL deadspace

0.5 mL for every 5 allergens requested

Specimen Stability Information
Specimen Type Temperature Time
​Serum ​ ​Refrigerated (preferred) ​14 days
​Frozen ​90 days
Interference

Some individuals with clinically insignificant sensitivity to allergens may have measurable levels of IgE antibodies in serum, and results must be interpreted in the clinical context.

False-positive results for IgE antibodies may occur in patients with markedly elevated serum IgE (>2,500 kU/L) due to nonspecific binding to allergen solid phases.

Performing Laboratory Information
Performing Location Day(s) Test Performed Report Available Methodology/Instrumentation
​Mayo Clinic Laboratories ​Monday through Friday ​1 to 3 days ​Fluorescence Enzyme Immunoassay (FEIA)
Reference Lab
Reference Range Information
Performing LocationReference Range













​Mayo Clinic Laboratories
ClassIgE kU/LInterpretation
0<0.10Negative
0/1 0.10-0.34Borderline/equivocal
10.35-0.69Equivocal
20.70-3.49Positive
33.50-17.4Positive
417.5-49.9Strongly positive
550.0-99.9Strongly positive
6> or =100Strongly positive

Reference values apply to all ages.


Interpretation

Detection of IgE antibodies in serum (Class 1 or greater) indicates an increased likelihood of allergic disease as opposed to other etiologies and defines the allergens that may be responsible for eliciting signs and symptoms.

The level of IgE antibodies in serum varies directly with the concentration of IgE antibodies expressed as a class score or kU/L.

Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​86003 ​1
Synonyms/Keywords
Bean
Common Bean
French Bean
Green Bean
Haricot Bean
Phaseolus vulgaris
Snap Bean
Wax Bean
Ordering Applications
Ordering Application Description
​Cerner ​Allergen, Grn String Bean (GSTB)
​COM ​Allergen, Green String Bean, IgE (GSTB)
If the ordering application you are looking for is not listed, contact your local laboratory for assistance.
Specimen Requirements
Fasting Required Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
​No ​Serum Serum Separator Tube (SST) ​Red Top Tube (RTT)
​0.3 mL
Collection Processing

​For 1 allergen: 0.3 mL
For more than 1 allergen: (0.05 mL x number of allergens) + 0.25 mL deadspace

0.5 mL for every 5 allergens requested

Specimen Stability Information
Specimen Type Temperature Time
​Serum ​ ​Refrigerated (preferred) ​14 days
​Frozen ​90 days
Interference

Some individuals with clinically insignificant sensitivity to allergens may have measurable levels of IgE antibodies in serum, and results must be interpreted in the clinical context.

False-positive results for IgE antibodies may occur in patients with markedly elevated serum IgE (>2,500 kU/L) due to nonspecific binding to allergen solid phases.

Useful For

Establishing the diagnosis of an allergy to green string bean

Defining the allergen responsible for eliciting signs and symptoms 

Identifying allergens:

- Responsible for allergic disease and/or anaphylactic episode

- To confirm sensitization prior to beginning immunotherapy

- To investigate the specificity of allergic reactions to insect venom allergens, drugs, or chemical allergens

Testing for IgE antibodies is not useful in patients previously treated with immunotherapy to determine if residual clinical sensitivity exists, or in patients in whom the medical management does not depend upon identification of allergen specificity.

Reference Range Information
Performing LocationReference Range













​Mayo Clinic Laboratories
ClassIgE kU/LInterpretation
0<0.10Negative
0/1 0.10-0.34Borderline/equivocal
10.35-0.69Equivocal
20.70-3.49Positive
33.50-17.4Positive
417.5-49.9Strongly positive
550.0-99.9Strongly positive
6> or =100Strongly positive

Reference values apply to all ages.


Interpretation

Detection of IgE antibodies in serum (Class 1 or greater) indicates an increased likelihood of allergic disease as opposed to other etiologies and defines the allergens that may be responsible for eliciting signs and symptoms.

The level of IgE antibodies in serum varies directly with the concentration of IgE antibodies expressed as a class score or kU/L.

For more information visit:
Performing Laboratory Information
Performing Location Day(s) Test Performed Report Available Methodology/Instrumentation
​Mayo Clinic Laboratories ​Monday through Friday ​1 to 3 days ​Fluorescence Enzyme Immunoassay (FEIA)
Reference Lab
For billing questions, see Contacts
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​86003 ​1